JLS-35WY  High voltage metering box
+
  • JLS-35WY  High voltage metering box
Zhengzhou KBT Transformer Instrument Co., Ltd.

JLS-35WY High voltage metering box

This type of high-voltage combined transformer is improved on the basis of similar products and is cast from imported outdoor special insulation resin from abroad. It has the characteristics of arc resistance, ultraviolet resistance, aging resistance, and long life. It is suitable for metering of active and reactive power in AC power systems with a rated frequency of 50HZ and a rated current of 35KV. It is especially suitable for small substations with unattended and oil-free products. The product performance meets GB requirements.

Categories:

High voltage metering box

Overview

This type of high-voltage combined transformer is improved on the basis of similar products and is cast from imported outdoor special insulation resin from abroad. It has the characteristics of arc resistance, ultraviolet resistance, aging resistance, and long life. It is suitable for metering of active and reactive power in AC power systems with a rated frequency of 50HZ and a rated current of 35KV. It is especially suitable for small substations with unattended and oil-free products. The product performance meets GB requirements.

Model and meaning

Structure introduction

The combined transformer consists of three single-phase voltage transformers (PT) and three current transformers (CT); the voltage transformer and current transformer are vacuum casted into one by a special outdoor insulation material (Swiss CibaCW5837). It is small in size and has the characteristics of high thermal stability, high precision, low magnetic density, overvoltage resistance, light weight, and easy installation. The secondary winding of the current transformer has taps to obtain different current ratios.

The secondary outlet terminal has a wiring protection box, and there is a wiring hole below it, which is convenient to connect, safe and reliable, and can prevent power theft. There are four mounting holes on the base channel steel for installation.

Technical data

This type of combined transformer reference standard

GB/T 20840.1-2010 "Transformers Part 1: General Technical Requirements"

GB/T 20840.4-2015 "Transformer Part 4: Technical Requirements for Supplementary Combined Transformer"

Rated voltage: 35kV

Rated frequency: 50Hz

Rated insulation level: 40.5/95/200 kV  

Rated voltage ratio: 35/√3/0.1/√3kV

Rated primary current: 5~600A; Rated secondary current: 5A or 1A

Rated capacity: PT: 0.2 level, 3×20/30VA; CT: 0.2S level, 3×15VA

Rated short-term thermal current (Ith) multiple: 100In/Is

Rated dynamic stable current (Idyn) multiple: 2.5Ith

Rated load power factor: cosФ=0.8 (hysteresis), FS≤10

Ambient temperature: between -25℃ and 40℃, the average daily temperature shall not exceed 35℃

Dirt level: Level IV

Altitude: no more than 1000m

Wiring diagram   

 

Appearance and installation dimensions

When installing a resonator on the N-terminal, the resonator must use weak insulation (D type) product.

Ordering instructions

1. Current ratio

2. Secondary cable length

3. Other special requirements

Things to note

1. After wiring, check whether all wiring is correct, especially the voltage secondary outlets a-b and c-b, and the current secondary outlets xS1 and xS2 or xS3 cannot form an open circuit.

2. The base ground terminal must be grounded on the site, and the transformer secondary outlet wire is reliably connected to ground according to regulations. Please note that the double-variable current secondary terminals S2 and S3 cannot be grounded at the same time.

3. The primary line installation must be P1 as the incoming side and P2 as the outgoing side.

4. Pay attention to protecting the terminal board and umbrella group during handling and hoisting.

Key words:

High voltage metering box

high voltage metering box

Get A Quote

Leave your contact information and get a free product quote

Related Products

Zhengzhou KBT Transformer Instrument Co., Ltd. is a specialized production enterprise mainly based on power transformers, which integrates product development,production, sales, service and technology consulting.

LZZBJ9-10C(175b4)


This series of current transformers features an epoxy‑resin‑cast, fully enclosed insulation design. They are suitable for use in power systems with a rated frequency of 50 Hz or 60 Hz for electrical energy metering. These transformers eliminate oil contamination and fire hazards, reduce maintenance requirements, and meet the demands of oil‑free operation.

LZZBJ4-35


The LZZB current transformer is an epoxy‑resin‑cast, fully enclosed device, primarily intended for power systems with a rated frequency of 50 Hz or 60 Hz and a rated voltage of 35 kV or lower. Its core function is to provide high‑accuracy current signals for energy metering, current measurement, and relay protection. This model features excellent dynamic and thermal stability, high accuracy, and a large capacity.

LZZB9-10A


The LZZBJ9-10A current transformer is primarily designed for indoor power systems with a rated frequency of 50 Hz and a rated voltage of 10 kV or less (with a maximum operating voltage of 12 kV). Its core functions are to accurately measure current and electrical energy in the circuit and to provide reliable signals to relay protection devices. This model is widely used in indoor switchgear—such as center‑mounted switchgear and cubicle switchgear—as well as in complete high‑ and low‑voltage equipment sets.

LZZB1-35W


The LZZB1-35W current transformer is an epoxy‑resin‑cast, fully enclosed device, primarily intended for power systems with a rated frequency of 50 Hz or 60 Hz and a rated voltage of 35 kV or lower. Its core function is to provide high‑accuracy current signals for energy metering, current measurement, and relay protection. This model is specifically designed to interface with equipment such as the ZW‑type 35 kV vacuum circuit breaker, offering superior dynamic and thermal stability, high accuracy, and large capacity.