20-24kV three-phase oil-immersed transformer
Oil-immersed on-load tap-changing transformers utilise on-load automatic voltage regulation functionality to maintain stable output voltage in real time, protect electrical equipment, and reduce line losses. They are suitable for areas with poor voltage stability, such as rural grids, remote mountainous regions, and older urban areas, where high line impedance or significant load fluctuations (e.g., nighttime voltages as high as 250V and daytime voltages below 170V) necessitate dynamic voltage regulation to ensure power supply quality. These transformers are specifically designed to deliver exceptional performance, efficiency, and reliability in various industrial environments.
Categories:
Transformer




Oil-immersed on-load tap-changing transformer
Oil-immersed on-load tap-changing transformers utilise on-load automatic voltage regulation functionality to maintain stable output voltage in real time, protect electrical equipment, and reduce line losses. They are suitable for areas with poor voltage stability, such as rural grids, remote mountainous regions, and older urban areas, where high line impedance or significant load fluctuations (e.g., nighttime voltages as high as 250V and daytime voltages below 170V) necessitate dynamic voltage regulation to ensure power supply quality. These transformers are specifically designed to deliver exceptional performance, efficiency, and reliability in various industrial environments.
One of the core advantages of our transformers lies in their outstanding energy efficiency, which helps reduce power losses and operational costs over the long term. With advanced design features and high-quality materials, these transformers can withstand harsh operating conditions while maintaining stable performance.
Oil-immersed on-load tap-changing transformers are widely applicable in high-rise buildings, commercial centres, subways, airports, stations, industrial and mining enterprises, drilling platforms, and oil production platforms. They are particularly suitable for use in fire-prone areas with harsh environmental conditions, such as zones containing flammable and explosive materials. Additionally, they can be used for power supply and lighting in residential areas, commercial streets, industrial and mining enterprises, and rural regions.
Product Parameter
|
Capacity(KVA) |
No-load Loss(W) |
Load Loss |
Impedance Voltage(%) |
No-load Current(%) |
Vector Group | Extend Connection | |
| Dyn11/Yzn11 | Yyno | ||||||
| 30 | 100 | 600 | 630 | 4.0 | 2.1 | Yyn0 OR Dyn11 |
±2*2.5% Or±5% |
| 50 | 130 | 870、 | 910 | 2 | |||
| 63 | 150 | 1090 | 1040 | 1.9 | |||
| 80 | 180 | 1310 | 1250 | 1.8 | |||
| 100 | 200 | 1580 | 1500 | 1.6 | |||
| 125 | 240 | 1890 | 1800 | 1.5 | |||
| 160 | 280 | 2310 | 2200 | 1.4 | |||
| 200 | 340 | 2730 | 2600 | 1.3 | |||
| 250 | 400 | 3200 | 3050 | 1.2 | |||
| 315 | 480 | 3830 | 3650 | 1.1 | |||
| 400 | 570 | 4520 | 4300 | 1.0 | |||
| 500 | 680 | 5410 | 5150 | 1 | |||
| 630 | 810 | 6200 | 4.5 | 0.9 | |||
| 800 | 980 | 7500 | 0.8 | ||||
| 1000 | 1150 | 10300 | 0.7 | ||||
| 1250 | 1360 | 12000 | 0.6 | ||||
| 1600 | 1640 | 14500 | 0.6 | ||||
| 2000 | 1940 | 18300 | 5.0 | ||||
| 2500 | 2290 | 21200 | |||||
| S11 35kv Three-phase Dual-winding No-load Voltage Regulation Transformer spec | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Rated Capacity (KVA) | Voltage Combination | Connection Group Symbol | No-load Loss (W) | Load Loss (W) | No-load Current (%) | Impedance Voltage (%) | L*W*H(mm) | Active parts Weight (kg) * Oil Weight (kg) | Total Weight (kg) | ||
| High Voltage (KV) | Tapping Range of High Voltage | Low Voltage (KV) | |||||||||
| 630 | 35 | ±2×2.5% 士5% | 3.15 6.3 10.5 | Ydl1 | 830 | 7860 | 0.65 | 6.5 | 2400*1700*221 | 2210*900 | 3250 |
| 800 | 980 | 9400 | 0.65 | 2500*1850*239 | 2350*1030 | 3500 | |||||
| 1000 | 1150 | 11500 | 0.65 | 2700*1950*251 | 2490*1180 | 3860 | |||||
| 1250 | 1400 | 13900 | 0.55 | 2900*2050*263 | 2600*1350 | 4350 | |||||
| 1600 | 1690 | 16600 | 0.45 | 3050*2130*275 | 2810*1580 | 4855 | |||||
| 2000 | 2170 | 18300 | 0.45 | 3105*2195*280 | 2800*1800 | 5300 | |||||
| 2500 | 2560 | 19600 | 0.45 | 3150*2535*298 | 3525*2060 | 7665 | |||||
| 3150 | 35-38.5 | ±2×2.5% 土5% | 3.15 6.3 10.5 | 3040 | 23000 | 0.45 | 7 | 3920*2725*284 | 3950*2205 | 8565 | |
| 4000 | 3610 | 27300 | 0.45 | 3310*2915*307 | 4825*2560 | 10115 | |||||
| 5000 | 4320 | 31300 | 0.45 | 3480*3020*314 | 5700*2635 | 11305 | |||||
| 6300 | 5240 | 35000 | 0.45 | 8 | 3590*2905*321 | 7120*3240 | 13510 | ||||
| 8000 | 35-38.5 | ±2×2.5% | 3.15 3.3 6.3 6.6 10.5 | Ynd11 | 7200 | 38400 | 0.35 | 4070*3050*359 | 8875*3840 | 16690 | |
| 10000 | 8700 | 45300 | 0.35 | 4106*2795*365 | 10305*3600 | 17690 | |||||
| 12500 | 1000 | 53800 | 0.3 | 4570*3010*384 | 12830*4310 | 20990 | |||||
| 16000 | 1210 | 65800 | 0.3 | 5235*3295*461 | 16010*6650 | 27660 | |||||
| 20000 | 1440 | 79500 | 0.3 | 5360*3415*466 | 18820*7600 | 32170 | |||||
| 25000 | 1700 | 94000 | 0.25 | 10 | 5830*3810*486 | 22360*9800 | 42600 | ||||
| 31500 | 2020 | 112000 | 0.25 | 6290*4290*526 | 25110*12010 | 49960 | |||||
| S11 35kv No-load Voltage Regulation Transformer Spec | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Rated Capacity (KVA) | Voltage Combination | No-load Loss (W) | Load Loss (W) | Impedance Voltage(%) | No-load Current (%) | L*W*H(mm) | Active parts Weight (kg) Oil Weight (kg) | Total Weight (kg) | ||
| High Voltage (KV) | Tapping Range of High Voltage | Low Voltage (KV) | ||||||||
| 50 | 35 38.5 | ±5% ±2×2.5% | 0.4 | 160 | 1200/1140 | 6.5 | 1.3 | 1195*935*1825 | 300*330 | 860 |
| 100 | 230 | 2010/1910 | 1.1 | 1200*995*1935 | 470*383 | 1130 | ||||
| 125 | 270 | 2370/2260 | 1.1 | 1235*940*1955 | 550*465 | 1335 | ||||
| 160 | 280 | 2820/2680 | 1 | 1285*895*1950 | 580*485 | 1475 | ||||
| 200 | 340 | 3320/3160 | 1 | 1310*1150*1985 | 680*595 | 1755 | ||||
| 250 | 400 | 3950/3760 | 0.95 | 1450*1090*2010 | 860*650 | 2000 | ||||
| 315 | 480 | 4750/4530 | 0.95 | 1930*1065*2320 | 980*765 | 2290 | ||||
| 400 | 580 | 5740/5470 | 0.85 | 1850*1165*2015 | 1170*885 | 2725 | ||||
| 500 | 680 | 6910/6580 | 0.85 | 2045*1205*2415 | 1340*960 | 3090 | ||||
| 630 | 830 | 7860 | 0.65 | 2085*1240*2515 | 1550*895 | 3810 | ||||
| 800 | 980 | 9400 | 0.65 | 2305*1615*2685 | 1990*1030 | 4510 | ||||
| 1000 | 1150 | 11500 | 0.65 | 2545*1540*2590 | 2415*1475 | 5055 | ||||
| 1250 | 1400 | 13900 | 0.6 | 2495*2010*2675 | 2480*1405 | 5290 | ||||
| 1600 | 1690 | 16600 | 0.6 | 2680*2100*2770 | 2600*1490 | 5450 | ||||
| 2000 | 1990 | 19700 | 0.55 | 2790*2180*2860 | 2720*1590 | 5600 | ||||
| 2500 | 2360 | 23200 | 0.55 | 2900*2290*2980 | 2830*1720 | 5760 | ||||
Drawing



Key words:
Get A Quote
Leave your contact information and get a free product quote
Related Products
Zhengzhou KBT Transformer Instrument Co., Ltd. is a specialized production enterprise mainly based on power transformers, which integrates product development,production, sales, service and technology consulting.
This series of current transformers features an epoxy‑resin‑cast, fully enclosed insulation design. They are suitable for use in power systems with a rated frequency of 50 Hz or 60 Hz for electrical energy metering. These transformers eliminate oil contamination and fire hazards, reduce maintenance requirements, and meet the demands of oil‑free operation.
The LZZB current transformer is an epoxy‑resin‑cast, fully enclosed device, primarily intended for power systems with a rated frequency of 50 Hz or 60 Hz and a rated voltage of 35 kV or lower. Its core function is to provide high‑accuracy current signals for energy metering, current measurement, and relay protection. This model features excellent dynamic and thermal stability, high accuracy, and a large capacity.
The LZZBJ9-10A current transformer is primarily designed for indoor power systems with a rated frequency of 50 Hz and a rated voltage of 10 kV or less (with a maximum operating voltage of 12 kV). Its core functions are to accurately measure current and electrical energy in the circuit and to provide reliable signals to relay protection devices. This model is widely used in indoor switchgear—such as center‑mounted switchgear and cubicle switchgear—as well as in complete high‑ and low‑voltage equipment sets.
The LZZB1-35W current transformer is an epoxy‑resin‑cast, fully enclosed device, primarily intended for power systems with a rated frequency of 50 Hz or 60 Hz and a rated voltage of 35 kV or lower. Its core function is to provide high‑accuracy current signals for energy metering, current measurement, and relay protection. This model is specifically designed to interface with equipment such as the ZW‑type 35 kV vacuum circuit breaker, offering superior dynamic and thermal stability, high accuracy, and large capacity.