Product Pictures




Introduction of SCB10 Dry Type Transformer
The Dry Type Pad Mounted Transformer is a highly efficient, reliable, and safe solution for electrical power distribution in both residential and commercial settings. Designed for outdoor use, this transformer is mounted on a concrete pad, making it ideal for areas where space is limited or for installations in urban environments. Unlike traditional oil-filled transformers, the dry type transformer uses air or resin for insulation, eliminating the risk of leaks and reducing the environmental impact.
Featuring a robust and compact design, the Dry Type Pad Mounted Transformer is built to withstand harsh weather conditions and provide reliable service over extended periods. It is particularly favored for applications that require low maintenance, as it operates without the need for regular oil checks or monitoring. The transformer is also equipped with advanced safety features, including temperature monitoring and overload protection, ensuring optimal performance and preventing potential hazards.
With its environmental benefits, ease of installation, and superior safety features, the Dry Type Pad Mounted Transformer is an excellent choice for both utility companies and industries looking for a sustainable and cost-effective power distribution solution. Its versatility and performance make it a critical component for modern electrical infrastructure.
Rated Capacity(KVA) | No Load Loss(W) | Load Loss(W) | Impedance (%) | Vector Group | Extend Connection | ||
| B(100) | F(120) | H(145) | |||||
| 30 | 190 | 670 | 710 | 760 | 4.0 | Yyn0 or Dyn11 | ±5% ±2*2.5% |
| 50 | 270 | 940 | 1000 | 1070 | |||
| 80 | 370 | 1290 | 1380 | 1480 | |||
| 100 | 400 | 1480 | 1570 | 1690 | |||
| 125 | 470 | 1740 | 1850 | 1980 | |||
| 160 | 540 | 2000 | 2130 | 2280 | |||
| 200 | 620 | 2370 | 2530 | 2710 | |||
| 250 | 720 | 2590 | 2760 | 2960 | |||
| 315 | 880 | 3270 | 3470 | 3730 | |||
| 400 | 980 | 3750 | 3990 | 4280 | |||
| 500 | 1160 | 4590 | 4880 | 5230 | |||
| 630 | 1340 | 5530 | 5880 | 6290 | |||
| 630 | 1300 | 5610 | 5960 | 6400 | 6.0 | ||
| 800 | 1520 | 6550 | 6960 | 7460 | |||
| 1000 | 1770 | 7650 | 8130 | 8760 | |||
| 1250 | 2090 | 9100 | 9690 | 10300 | |||
| 1600 | 2450 | 11000 | 11700 | 12500 | |||
| 2000 | 3050 | 13600 | 14400 | 15500 | |||
| 2500 | 3600 | 16100 | 17100 | 18400 | |||
| SC (B) 10 15~22KV voltage regulating power transformer without excitation Spec | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Model | Rated capacity (KVA) | Connection symbol | Voltage combination (KV) | No-load loss (W) | Load loss (W) | No-load curent (%) | Short circuit impedance(%) impedance | |||
| High- voltage | Tapping range | Low- voltage | 6 | |||||||
| SC10-50 | 50 | Yyno or Dynl1 | 15 20 22 | 士5% 士2×2.5% | 0.4 | 345 | 1180 | 2.4 | ||
| SC10-100 | 100 | 545 | 1910 | 2.2 | ||||||
| SC10-160 | 160 | 682 | 2780 | 1.8 | ||||||
| SC10-200 | 200 | 745 | 2820 | 1.8 | ||||||
| SC10-250 | 250 | 855 | 3280 | 1.6 | ||||||
| SC10-315 | 315 | 980 | 3910 | 1.6 | ||||||
| SC10-400 | 400 | 1165 | 4640 | 1.4 | ||||||
| SC10-500 | 500 | 1365 | 5550 | 1.4 | ||||||
| SC10-630 | 630 | 1545 | 6550 | 1.2 | ||||||
| SC10-800 | 800 | 1775 | 7910 | 1.2 | ||||||
| SC10-1000 | 1000 | 2090 | 9370 | 1 | ||||||
| SC10-1250 | 1250 | 2410 | 11050 | 1 | ||||||
| SC10-1600 | 1600 | 2820 | 13300 | 1 | ||||||
| SC10-2000 | 2000 | 3280 | 15690 | 0.8 | ||||||
| SC10-2500 | 2500 | 3910 | 18550 | 0.8 | ||||||
| SC (B)10 35KV voltage regulating power transformer without excitation Spec | ||||||||
|---|---|---|---|---|---|---|---|---|
| Model | Connection symbol | Voltage combination (KV) | No-load loss (W) | Load loss (W) | No-load current (%) | Short circuit impedance (%) | ||
| High- voltage | Tapping range | Low- voltage | ||||||
| SC10-800 | Dynll Yd11 Yyno
Ydll
YynO | 33~38.5 | ±5% ±2×2.5% | 3.5 | 2200 | 9400 | 1.1 | 6 |
| SC10-1000 | 6 | 2610 | 10800 | 1.1 | ||||
| SC10-1250 | 6.3 | 3060 | 11900 | 1 | ||||
| SC10-1500 | 10 | 3600 | 15400 | 1 | ||||
| SC10-2000 | 10.5 | 4130 | 18200 | 0.9 | 7 | |||
| SC10-2500 | 11 | 4750 | 21800 | 0.9 | ||||
| SC10-3150 | 5880 | 24500 | 0.8 | 8 | ||||
| SC10-4000 | 6860 | 29400 | 0.8 | |||||
| SC10-5000 | 8180 | 34960 | 0.7 | |||||
| SC10-6300 | 9680 | 40800 | 0.7 | |||||
| SC10-8000 | Dyn11
Ydl1
YNd11 | 11000 | 46060 | 0.6 | 9 | |||
| SC10-10000 | 6 | 12660 | 56500 | 0.6 | ||||
| SC10-12500 | 6.3 | 15400 | 64600 | 0.5 | ||||
| SC10-16000 | 10.5 | 18900 | 76000 | 0.5 | ||||
| SC10-20000 | 11 | 22400 | 85500 | 0.4 | 10 | |||
| SC (B) 10 11KV voltage regulating power transformer without excitation Spec | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model | Rated capacity (KVA) | Conmection symbol | Voltage combination (KV) | No-load loss (W) | Load loss (W) | (%) | No-load current Short circuit impedance (%) | ||
| High- voltage | Tapping range | Low. voltage | |||||||
| SC10-30 | 30 | YyuO or Dyul1 | 11 10.5 10 6.3 6 | m5% m2×2.5% | 0.4 | 190 | 710 | 2.4 | 4 |
| SC10-50 | 50 | 270 | 1000 | 2.4 | |||||
| SC10-80 | 80 | 370 | 1380 | 1.8 | |||||
| SC10-100 | 100 | 400 | 1570 | 1.8 | |||||
| SC10-125 | 125 | 470 | 1850 | 1.6 | |||||
| SCB10-160 | 160 | 550 | 2130 | 1.6 | |||||
| SCB10-200 | 200 | 630 | 2530 | 1.4 | |||||
| SCB10-250 | 250 | 720 | 2760 | 1.4 | |||||
| SCB10-315 | 315 | 880 | 3470 | 1.2 | |||||
| SCB10-400 | 400 | 980 | 3990 | 1.2 | |||||
| SCB10-500 | 500 | 1160 | 4880 | 1.2 | |||||
| SCB10-630 | 630 | 1350 | 5880 | 1 | |||||
| SCB10-630 | 630 | 1300 | 5960 | 1 | 6 | ||||
| SCB10-800 | 800 | 1520 | 6960 | 1 | |||||
| SCB10-1000 | 1000 | 1770 | 8130 | 1 | |||||
| SCB10-1250 | 1250 | 2090 | 9690 | 1 | |||||
| SCB10-1600 | 1600 | 2450 | 11730 | 1 | |||||
| SCB10-2000 | 2000 | 3050 | 14450 | 0.8 | |||||
| SCB10-2500 | 2500 | 3600 | 17170 | 0.8 | |||||
| SCB10-1600 | 1600 | 2450 | 12900 | 1 | 8 | ||||
| SCB10-2000 | 2000 | 3050 | 15890 | 0.8 | |||||
| SCB10-2000 | 2500 | 3600 | 18890 | 0.8 | |||||
| SG (B) 10 series non-encapsulated H class dry type transformer spec | |||||
|---|---|---|---|---|---|
| Model | Vector Group | no-load loss(W) | load loss(W) | impedance(%) | no-load current(%) |
| SG10-30/10 | Yyn0 OR Dyn11 | 190 | 760 | 4 | 2 |
| SG10-50/10 | 270 | 1070 | 2 | ||
| SG10-80/10 | 370 | 1480 | 1.5 | ||
| SG10-100/10 | 400 | 1690 | 1.5 | ||
| SG10-125/10 | 470 | 1980 | 1.3 | ||
| SG10-160/10 | 540 | 2280 | 1.3 | ||
| SG10-200/10 | 620 | 2710 | 1.1 | ||
| SG10-250/10 | 720 | 2960 | 1.1 | ||
| SG10-315/10 | 880 | 3730 | 1.0 | ||
| SG10-400/10 | 980 | 4280 | 1.0 | ||
| SG10-500/10 | 1160 | 5230 | 1.0 | ||
| SG10-630/10 | 1343 | 6290 | 0.85 | ||
| SG10-800/10 | 1520 | 7460 | 0.85 | ||
| SG10-1000/10 | 1770 | 8760 | 0.85 | ||
| SG10-1250/10 | 2090 | 10300 | 0.85 | ||
| SG10-1600/10 | 2450 | 12500 | 6 | 0.85 | |
| SG10-2000/10 | 3050 | 15500 | 0.7 | ||
| SG10-2500/10 | 3600 | 18400 | 0.7 | ||
Key words:
dry type transformer
Previous
Previous
Get A Quote
Leave your contact information and get a free product quote
Related Products
Zhengzhou KBT Transformer Instrument Co., Ltd. is a specialized production enterprise mainly based on power transformers, which integrates product development,production, sales, service and technology consulting.
This series of current transformers features an epoxy‑resin‑cast, fully enclosed insulation design. They are suitable for use in power systems with a rated frequency of 50 Hz or 60 Hz for electrical energy metering. These transformers eliminate oil contamination and fire hazards, reduce maintenance requirements, and meet the demands of oil‑free operation.
The LZZB current transformer is an epoxy‑resin‑cast, fully enclosed device, primarily intended for power systems with a rated frequency of 50 Hz or 60 Hz and a rated voltage of 35 kV or lower. Its core function is to provide high‑accuracy current signals for energy metering, current measurement, and relay protection. This model features excellent dynamic and thermal stability, high accuracy, and a large capacity.
The LZZBJ9-10A current transformer is primarily designed for indoor power systems with a rated frequency of 50 Hz and a rated voltage of 10 kV or less (with a maximum operating voltage of 12 kV). Its core functions are to accurately measure current and electrical energy in the circuit and to provide reliable signals to relay protection devices. This model is widely used in indoor switchgear—such as center‑mounted switchgear and cubicle switchgear—as well as in complete high‑ and low‑voltage equipment sets.
The LZZB1-35W current transformer is an epoxy‑resin‑cast, fully enclosed device, primarily intended for power systems with a rated frequency of 50 Hz or 60 Hz and a rated voltage of 35 kV or lower. Its core function is to provide high‑accuracy current signals for energy metering, current measurement, and relay protection. This model is specifically designed to interface with equipment such as the ZW‑type 35 kV vacuum circuit breaker, offering superior dynamic and thermal stability, high accuracy, and large capacity.