LZJC-10Q
The LZJC-10Q current transformer is primarily designed for use in indoor power systems with a rated frequency of 50 Hz (or 60 Hz) and a rated voltage of 10 kV or less. Its core function is to accurately measure the current and electrical energy in the circuit and to provide signals to relay protection devices.
Categories:
Current transformer
Technical data
| 型号 | 额定一次电流(A) | 准确级 | 额定二次输出 | 短时热电流(kA/s) | 额定动稳定电流(kA) | ||||
| 0.2S,0.5S | 0.2 | 0.5 | 10P10 | 10P15 | |||||
| LJZC-10Q | 5~40 | 0.2(S)/10P 0.5(S)/10P |
10 | 10 | 15 | 30 | 50 | 100In/1 | 250In |
| 50~400 | |||||||||
| 500 | 25/4 | 63 | |||||||
| 600 | 31.5/4 | 80 | |||||||
| 800 | 40/4 | 100 | |||||||
| 1000 | |||||||||
Overall dimension drawing


Key words:
Current transformer
Previous
Next
Previous
Next
Get A Quote
Leave your contact information and get a free product quote
Related Products
Zhengzhou KBT Transformer Instrument Co., Ltd. is a specialized production enterprise mainly based on power transformers, which integrates product development,production, sales, service and technology consulting.
The LXK Series zero-sequence current transformers are primarily suitable for small-ground-current systems with a rated frequency of 50 Hz or 60 Hz and a rated voltage of 35 kV or less. Their core function is to work in conjunction with DD-11/60 or DD-1/60 relays and signaling devices to detect zero-sequence current (residual current) in three-phase power systems. When asymmetric faults, such as single-phase-to-ground faults, occur in the system, the current transformers can accurately detect them and trigger protective devices, thereby providing ground fault protection and monitoring for cables.
This series of current transformers features a fully enclosed structure with epoxy resin cast insulation. They are suitable for use in power systems with a rated frequency of 50 Hz or 60 Hz for electricity metering. This type of current transformer eliminates oil contamination and fire hazards, reduces maintenance requirements, and meets the requirements for oil-free operation. This type of current transformer uses epoxy resin as the primary insulation material, offering resistance to arcing, UV radiation, and aging. The core is made of high-quality, highly permeable material that has undergone annealing treatment. Both the primary and secondary windings, as well as the core, are encapsulated in epoxy resin, ensuring excellent insulation performance.
This series of current transformers features a fully enclosed structure with epoxy resin cast insulation. They are suitable for use in power systems with a rated frequency of 50 Hz or 60 Hz for electricity metering. This type of current transformer eliminates oil contamination and fire hazards, reduces maintenance requirements, and meets the requirements for oil-free operation. This type of current transformer uses epoxy resin as the primary insulation material, offering resistance to arcing, UV radiation, and aging. The core is made of high-quality, high-permeability material that has undergone annealing treatment. Both the primary and secondary windings, as well as the core, are encapsulated in epoxy resin, ensuring excellent insulation performance.
This series of current transformers features a fully enclosed structure with epoxy resin cast insulation. They are suitable for use in power systems with a rated frequency of 50 Hz or 60 Hz for electricity metering. This type of current transformer eliminates oil contamination and fire hazards, reduces maintenance requirements, and meets the requirements for oil-free operation. These transformers use epoxy resin as the primary insulation material, offering resistance to arcing, UV radiation, and aging. The core is made of high-quality, high-permeability material that has undergone annealing treatment. Both the primary and secondary windings, as well as the core, are encapsulated in epoxy resin, ensuring excellent insulation performance.







